In order to interact with a database, such as running a query, the first thing is to set up the connection against the target database. A connection is a set of configuration (in Nexial data file) that describe how a database session can be established. It can be referenced by a single name, which allows for reusability and appropriate connectivity separation.

To describe a connection, add the following to the appropriate data file: setup

You can substitute mydb with something else more readable (without dot).

IMPORTANT !!! Note that only the following are required:

  • <connection name> .type - this specifies the type of database to connect. Nexial will use this data to load the appropriate connection driver (a.k.a. JDBC driver). The valid values (currently supported drivers) are:
    • db2 (IBM DB2, JDBC type 4)
    • mssql (Microsoft SQL Server)
    • oracle (Oracle, JDBC type 4)
    • postgresql (PostgreSQL)
    • mysql (MySQL)
    • sqlite (SQLite)
    • hsqldb (HyperSQL)
    • isam or connx (ISAM/Connx, JDBC type 2)
    • mongodb (see below for more details)
    • mariadb (MariaDB)
    • To connect to other database not mentioned above, you may do the following:
      1. Add the appropriate JDBC Type 4 driver (jar file) to ${user.home}/.nexial/jar or ${NEXIAL_HOME}/lib directory.

        Find more details about How to copy custom jars here.
      2. Add the appropriate driver class name to <connection name>.JavaClassName data variable (instead of <connection name>.type). Check the vendor’s support page for the correct driver jar and driver classname.
      3. If you have any dll file which is required to load then you can add it to ${user.home}/.nexial/dll directory. Example: mssql requires a dll file if integratedSecurity (for window authentication) is true in the url, system will automatically download the dll file while downloading the driver but if you have to use some different dll you can place here.
  • <connection name> .url - this specifies how to connect to the target database. Some connection string may contain username and password. Hence the .username and .password are required. For more details about connection string, check the following links:

In addition to the above, there are other useful configurations:

  1. <connection name> .user - the username to use to connect to the target database.
  2. <connection name> .password - the password to use to connect to the target database.
  3. <connection name> .autocommit - specifies if the executions (e.g. INSERT, DELETE, UPDATE) carried out via this connection should be treated as individual transaction or as a single transaction. This configuration only makes sense when executing multiple SQL statements within one command. Executing a single SQL statement within 1 command is always treated as a single transaction. .autocommit set to true means that each SQL statement within one command is treated as individual transaction. .autocommit set to false means the commit will only occur after all the SQL statements are executed successfully - any failure will force a rollback.
  4. <connection name> .treatNullAs - specifies how NULL value should be represented. By default, a NULL  value will be treated as an empty string.  For example, let’s say that a query returns 2 rows of 3 columns each. The first row has a NULL value for col2, the second row as a empty string for col2.
col1 col2 col3
ABC NULL 123
DEF     456

if `.treatNullAs` is not defined or set to `(empty)`, then the output via [`runSQL(var,db,sql)`](runSQL(var,db,sql)) would look like:

col1 col2 col3
ABC   123
DEF     456

if `.treatNullAs` is defined as ``, then the output via  [`runSQL(var,db,sql)`](runSQL(var,db,sql)) would look like:

col1 col2 col3
ABC <null> 123
DEF     456

Multiple connections within one test script

It is not uncommon that multiple connections are needed within one test script. To differentiate between different connections, set up multiple connections in the appropriate Nexial data file:
setup2

Then in test script, reference the appropriate connection via its name (i.e. mydb or app2):